Models of cars considered in the real Management are equipped with system of additional safety (SRS). Before starting performance of any works near the block of a safety cushion, a steering column or the dashboard, disconnect SRS in order to avoid receiving traumas at its casual operation. Electroconducting of a chain of SRS is easy for distinguishing on yellow color of isolation. |
1. In chains of indexes of turns and the alarm system the general breaker is used. 2. Serviceability of functioning of the breaker proves to be true distinctly heard rhythmical clicking. Failure of one of control lamps leads to the termination of functioning of the breaker. At refusal of one of indexes frequency of operation of the breaker doubles, informing the driver on need of performance of replacement of a lamp. 3. Simultaneous refusal of both indexes with high degree of probability testifies to failure of the corresponding safety lock. Refusal possibility actually the breaker, or the podrulevy switch is not excluded also. Check a condition of contact connections of electroconducting of the corresponding chain. At knocking-out of a safety lock check electroconducting on existence of signs of short circuit.
|
4. For replacement of the breaker disconnect from it electroconducting and liberate assembly from the basic arm located under the dashboard, to the right of a steering column. |
5. Track, that the replaceable breaker on the standard size corresponded failed. 6. Installation is made upside-down. |